APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2743 Issued:1975-08-18
Revised:2012-01-10
Style 2743 Laminated flat cable

Rating105 deg C, 90 Vac, Horizontal flame.
Conductor36 AWG - 12 AWG round or flat, copper, tin plated copper, nickel plated or silver plated copper or copper alloy
InsulationSolid PET, 1.0 mil minimum thickness at any point. Top and bottom insulation bonded together with 3.0 mils minimum thickness at any point of PVC or 1.5 mils minimum of polyester adhesive. Insulation width on the outside of the conductors not less than 15 mils and not less than 15 mils width between conductors. Length of conductors not specified.
AssemblyTwo through 150 conductors laid parallel and in one plane.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment (such as computers and business machines) and appliances.