Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Insulated Conductor | Labeled or complies with Manufacturer's AWM Procedure having a minimum rating of 80 deg C, 300 Vac, 16 AWG maximum. May include mixed AWG sizes.
|
|
Assembly | From 2 to 100 insulated singles bonded together laid parallel in one plane over the ground plane and laminated between 2 sheets of extruded PVC providing minimum 50 mils edge width. May include two or more groups of bonded singles, each with a separate ground plane. All groups laid flat in one plane may be separated by a web formed by laminated jacket. Manufacturer shall maintain a record of all singles used in each cable.
|
|
Ground Plane | Flat tinned copper braid, 40 mils maximum thickness. |
|
Jacket | Extruded PVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|