Rating | 80 deg C, 30 Vac, Horizontal Flame. |
|
Conductor | 40 AWG min, Flat or Round. Flat conductors max 6 mils thick, 100 mils wide. |
|
Insulation | Non-Extruded Laminated PET or Non-Extruded Laminated PVC, 4 mils min average. Composite sheets of 1 mil PET and 4 mils PVC each side. Min 1 mil insulation over the conductors. |
|
Assembly | Two to 100 uninsulated conductors laid parallel in one plane, laminated between 2 composite sheets of PET and PVC. May include mixed AWG sizes. Min 8 mils between conductors, 40 mils min edge width. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Class 2 circuits in electronic equipment. |
|