APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2753 Issued:1975-10-15
Revised:2012-07-16
Style 2753 Multiple-conductor cable using non-inegral jacket

Rating80 deg C, 30 Vac(section A), 300 Vac(section B), Cable flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled style 1061 and Extruded PE with 15 Mils Minimum average, 13 mils minimum at any point
AssemblyThe cable consists of two groups of insulated conductors (lay of individual conductors not specified). The two groups are laid parallel with an overall PVC jacket and an interconnecting web. Section A - four single conductors 22 AWG, labelled Style 1061. two pair labeled Style 1061. two pair 26 AWG with Polyethylene Insulation (15 Mils Minimum average, 13 mils minimum at any point) with each pair shielded (Polyester/Aluminum) - unjacketed. Section B - two, three or four single conductors 18 AWG, labeled Style 1061. two pair 24 AWG, labelled Style 1061. thickness of web not specified.
ShieldMetallic, Each section may be shielded.
JacketExtruded PVC, 35 mils min average, 28 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection cable where terminated in connectors.

UL and the UL Logo are trademarks of UL LLC © 2024