Rating | 80 deg C, 30 Vac(section A), 300 Vac(section B), Cable flame. |
|
Conductor | 30 AWG - 16 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled style 1061 and Extruded PE with 15 Mils Minimum average, 13 mils minimum at any point |
|
Assembly | The cable consists of two groups of insulated conductors (lay of individual conductors not specified). The two groups are laid parallel with an overall PVC jacket and an interconnecting web.
Section A - four single conductors 22 AWG, labelled Style 1061. two pair labeled Style 1061. two pair 26 AWG with Polyethylene Insulation (15 Mils Minimum average, 13 mils minimum at any point) with each pair shielded (Polyester/Aluminum) - unjacketed.
Section B - two, three or four single conductors 18 AWG, labeled Style 1061. two pair 24 AWG, labelled Style 1061. thickness of web not specified. |
|
Shield | Metallic, Each section may be shielded. |
|
Jacket | Extruded PVC, 35 mils min average, 28 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection cable where terminated in connectors. |
|