Rating | 80 deg C, voltage not specified, Horizontal Flame, Cable Flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedures. May use same or mixed AWG size. |
|
Assembly | Consists of two or more insulated conductors, twisted pairs or groups of twisted insulated conductors twisted together. The insulated conductors or groups of insulated conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional - Extruded PVC. |
|
Inner Shield | Optional. |
|
Center Shield | Optional. |
|
Outer Shield | Optional. |
|
Outer Shield | Optional. |
|
PVC | Extruded PVC. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.250 or less | 15 mils | 12 mils |
| 0.251-0.425 inch | 30 mils | 24 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or test probe leads for electronic testing and measuring equipment. |
|