APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2754 Issued:1975-11-24
Revised:2011-10-14
Style 2754 Multiple-conductor cable with non-integral jacket

Rating80 deg C, voltage not specified, Horizontal Flame, Cable Flame.
Insulated ConductorLabeled or complying with manufacturer's AWM procedures. May use same or mixed AWG size.
AssemblyConsists of two or more insulated conductors, twisted pairs or groups of twisted insulated conductors twisted together. The insulated conductors or groups of insulated conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional - Extruded PVC.
Inner ShieldOptional.
Center ShieldOptional.
Outer ShieldOptional.
Outer ShieldOptional.
PVCExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.250 or less15 mils12 mils
0.251-0.425 inch30 mils24 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or test probe leads for electronic testing and measuring equipment.