APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2772 Issued:1976-01-14
Revised:2019-11-06
Style 2772 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating60 deg C, 150 Vac, Cable flame.
Conductor30 AWG - 18 AWG solid or stranded round.
InsulationExtruded PP, 12 mils min average, 11 mils minimum at any point.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional
Covering(Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
major dia in inches
0.395 or less30 mils min average24 mils minimum at any point
0.396 to 0.500 dia35 avg30 min
0.501 to 0.700 dia50 avg43 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024