Rating | 60 deg C, 150 Vac, Cable flame. |
|
Conductor | 30 AWG - 18 AWG solid or stranded round. |
|
Insulation | Extruded PP, 12 mils min average, 11 mils minimum at any point. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional |
|
Covering | (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | Extruded PVC |
| major dia in inches |
| 0.395 or less | 30 mils min average | 24 mils minimum at any point |
| 0.396 to 0.500 dia | 35 avg | 30 min |
| 0.501 to 0.700 dia | 50 avg | 43 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnect of electronic equipment. |
|