APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2773 Issued:1976-02-26
Revised:2012-04-20
Style 2773 Bonded or laminated flat ribbon cable.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, material not specified. May include mixed AWG sizes.
InsulationExtruded PVC, 6 mils minimum average thickness.
AssemblyTwo to fifty uninsulated wires laid parallel in one plane, laminated between 2 sheets of PVC, each sheet is 6 mils minimum average, 5 mils minimum conductors, 15 mils minimum edge width. Irradiation optional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.