Rating | 80 deg C, Voltage not specified, Cable flame. |
|
Insulation | AWM Styles 5073, 5074, 5075, 5085, 5102, 5120, 5121 or 5122. |
|
Assembly | Two or more twisted insulated singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC |
| Diameter of cable under jacket (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.250 or less | 15 | 12 |
| 0.251-0.425 | 30 | 23 |
| 0.426-0.700 | 45 | 36 |
| 0.701-1.000 | 60 | 48 |
| 1.001-1.500 | 80 | 62 |
| 1.501-2.500 | 110 | 88 |
| 2.501 or larger | 140 | 112 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Electronic Equipment. |
|