APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2775 Issued:1976-02-17
Revised:2012-04-23
Style 2775 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 250 Vac, Cable flame, 75 deg C Wet.
ConductorResistance Wire. Nickel, copper alloy or copper, sizes vary depending upon wattage demand. May be spirally wound around a thread core.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point. Required QMTT2 PVC Compound suitable for 75 deg C Wet or See Facing Page for PVC Compound.
AssemblyTwo conductors, cable consists of the insulated single laid parallel with an overall jacket and an interconnecting web with 40 mils minimum thickness at any point.
ShieldOptional - May be provided with a shield over the insulated single.
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating Cable for Pipe Heating Units.

UL and the UL Logo are trademarks of UL LLC © 2024