APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2778 Issued:1976-04-08
Revised:2019-11-12
Style 2778 Jacketed Cord.

Rating60 deg C, 150 Vac, Cable flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with Manufacture's AWM Procedure.
AssemblyTwo or more twisted insulated singles or groups of insulated singles twisted together. Lay not specified. Barrier layer optional. Manufacturer shall maintain a complete description of each assembly. Fillers - Required if necessary to form a relatively smooth round core for extrusion of outer jacket.
ShieldOptional.
CoveringOptional) A nominal 15 mil PVC covering may be extruded over the conductor assembly.
JacketPVC
dia in inches
0.425 or less30 mils min average28 mils minimum at any point
0.426-0.700 dia60 avg48 min
0.701-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024