APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2779 Issued:1976-04-15
Revised:2013-01-17
Style 2779 Laminated flat ribbon cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 24 AWG, solid or stranded.
InsulationPVC sheets, 12 mils minimum average thickness, 8 mils minimum thickness at any point, bonded each side of conductors, 34 mils minimum distance between conductors, 15 mils minimum edge width.
AssemblyTwo to 100 conductors laid parallel in one plane.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024