APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2782 Issued:1976-03-09
Revised:2010-08-03
Style 2782 Electronic Cable.

Rating60 deg C, No voltage assigned, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare, copper, copper-clad steel, or copper alloy.
InsulationPE, 20 mils min average, 18 mils minimum at any point.
AssemblyTwo conductors (insulated conductor and one labeled style 1004} laid parallel or twisted.
ShieldOne or both may employ metal serve, braid or equivalen conductive thermoplastic with drain wire, or aluminum-faced Polyester with drain wire. Double shielding consisting of two or combination of two of the above may be employed.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection of Medical and Dental Electro-Surgical Hand Instruments.
 