APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2785 Issued:1976-06-01
Revised:2019-11-06
Style 2785 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. the conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
Covering(Optional) - A 6 mil or heavier extruded PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
major dia in inches
0.250 or less15 mils min average12 mils minimum at any point
0.25l-0.700 dia30 avg24 min
0.701-1.000 dia60 avg48 min
l.00l-l.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.