Rating | 80 deg C, 150 Vac, Cable flame. |
|
Conductor | 30 AWG - 16 AWG, solid or stranded, tinned or bare copper. |
|
Insulation | Labeled or Complying with manufacturer's AWM Procedure and having a minimum rating of 80 deg C and 150 Volts.. |
|
Filler | Required if necessary to form a relatively smooth round core for extrusion of outer jacket. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving or braid; paper; nylon; PET; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Covering | Optional. Extruded PVC, 15 mils minimum average thickness, may be extruded over the conductor assembly. |
|
Shield | Optional. 36 AWG - 30 AWG, tinned or untinned copper applied as a wrap or braid or a wrap of aluminum faced Polyester tape. An uninsulated drain wire may be used. The shield may be over one or more of the insulated conductors or applied between the conductors assembly and the optional covering. |
|
Jacket | Extruded XLPVC |
| Dia. of cable under Jacket in inches | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.700 or less | 30 | 23 |
| 0.70l-l.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of Electronic Equipment. |
|