APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2791 Issued:1976-06-04
Revised:2020-08-27
Style 2791 Multi-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, VW-1 flame
Conductor40 AWG minimum, material not specified.
InsulationExtruded PE, Extruded Foamed PE, Extruded FRPE, Extruded Foamed FRPE, 4 mils minimum at any point, 100 mils maximum, may be radiation or chemically cross-linked.
AssemblyTwo to ten conductors laid parallel or twisted together, consists of optional inner covering, required shield over any and/or all singles, required jacket, optional shield over jacket and optional outer covering over jacket. Length of lay not specified. Barrier layer or fillers optional.
ShieldRequired, over any and/or all singles. Optional, over jacket.
CoveringInner Covering, optional, over any or all singles, 2 mils minimum at any point, Extruded PVC, Extruded Polyimide, Extruded Polyester, Extruded PVDF, Extruded ETFE or Non-extruded Lacquered Braid. Outer Covering, optional, over jacket, Extruded PVC, 5 mils minimum at any point, 40 mils maximum.
JacketExtruded PVC, 5 mils minimum average, 3 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of Low Energy Non-Hazardous Circuits in Audio and Video Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024