APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2792 Issued:1976-06-08
Revised:2012-04-06
Style 2792 Parallel cable with extruded integral insulation and jacket

Rating60 deg C, 30 Vac, Horizontal Flame, VW-1 Flame.
Conductor32 AWG - 16 AWG, solid or stranded. May include an uninsulated grounding conductor.
InsulationExtruded PE, FRPE, XLPE or XLFRPE, solid or foamed. 18 mils - 100 mils minimum thickness at any point.
AssemblyTwo insulated conductors. Similar to flexible cord type NISPT.
ShieldOver each insulated conductor.
JacketExtruded PVC. 10 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of low energy non-hazardous circuits in audio and video equipment.