APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2801 Issued:1976-06-22
Revised:2012-07-16
Style 2801 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor26 AWG, 24 AWG, 22 AWG, solid or stranded.
Insulation1 Single-conductor 22 AWG, Labeled Style 1061. 2 Pair-conductor 26 AWG, Labeled Style 1061. 2 Pair-conductor 24 AWG, Labeled Style 1061. 2 pair-conductor 26 AWG, extruded PE, 15 mils minimum average, 13 mils minimum at any point.
AssemblySeven conductors.
ShieldEach pair shielded (Polyester/aluminum) with drain 26 AWG, and overall Polyester tape.
JacketExtruded PVC, 30 mils min average, 23 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring

UL and the UL Logo are trademarks of UL LLC © 2024