APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2803 Issued:1976-07-29
Revised:2012-04-20
Style 2803 Multiple Conductor with Extruded and Extruded Non-Integral Jacket.

Rating60 deg C, 30 Vac, Horizontal flame or Cable flame.
Conductor46 AWG - 10 AWG solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM Procedure.(style 1605) The designation of all styles used in making up the cable are available.
AssemblyTwo or more twisted insulated singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Diameter of assembly under jacket 0.6 inch max.
ShieldOptional.
CoveringInner Covering - (Optional) Extruded PVC, 4 mil minimum average thickness.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or external interconnection of Class 2 Circuits in Electronic Equipment.