APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2804 Issued:1976-07-29
Revised:2012-07-26
Style 2804 Multi-conductor cable with extruded insulation.

Rating80 deg C, 300 Vac, VW-1 flame.
Conductor24 AWG - 20 AWG solid or stranded round.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point.
AssemblyTwo conductors. Distance between conductors (measured from center to center) shall be 0.285 in. min. for 20 AWG., 0.250 in. min. for 22 AWG; and 0.230 in. min. for for 24 AWG.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Radio and Television Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024