APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2805 Issued:1976-08-26
Revised:2011-08-11
Style 2805 Parallel Cable with Extruded Integral Insulation and Jacket

Rating60 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG minimum. Material not specified. May include an uninsulated grounding conductor.
InsulationSolid or cellular FRPE or PE, 7 mils minimum thickness at any point, 100 mils maximum. May be irradiated.
AssemblyTwo conductors.
ShieldOver each insulated conductor.
JacketPVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
Misc.Barrier - Optional, over each shield.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of Low Energy Non-Hazardous Circuits in Audio and Video Equipment.