Rating | 90 deg C, 90 Vac, Horizontal flame. |
|
Conductor | 36 AWG - 10 AWG plated, round or flat, straight or irregular shaped. |
|
Insulation | Non-Extruded PET, PETP 1.0 mil minimum thickness at any point. Top and bottom insulation bonded together with 3.0 mils minimum thickness at any point PVC, or 1.5 mils minimum of polyester adhesive. 15 mils minimum distance between adjacent conductors. 15 mil minimum insulation edge width. |
|
Assembly | Two through 150 conductors laid parallel and in one plane. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Appliances. |
|