APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2807 Issued:1959-05-01
Revised:2012-02-02
Style 2807 Multi-coductor Laminated Flat Ribbon Cable.

Rating90 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 10 AWG round or flat, straight or irregular shaped.
InsulationPET film, 1.5 mils minimum thickness, bonded each side of conductors with PVC or 1.5 mils minimum thickness of Polyester adhesive. 16 mils minimum edge width and 16 mils minimum distance between conductors.
AssemblyTwo through 150 conductors laid parallel and in one plane.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024