Style 2812 Bonded or laminated flat ribbon cable.

Rating105 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure having a minimum rating of 105 deg C and 300 V.
AssemblyTwo to 100 insulated singles or twisted pairs, bonded to solid or cellular PVC or irradiated PVC sheet, or 0.2 mil minimum PETP film bonded with 0.1 mil minimum polyester or PVC adhesive, or 0.2 mil minimum PETP film bonded with 3 mil minimum PVC. Same or mixed AWG.
ShieldOptional.
CoveringOptional, extruded PVC, 5 mils minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.