APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2813 Issued:1976-08-26
Revised:2012-02-24
Style 2813 Bonded Flat Ribbon Cable.

Rating105 deg C, 600 Vac, Horizontal flame.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure having a minimum rating of 105 deg C, 600 Vac.
AssemblyFrom 2 to 100 insulated singles or twisted pairs, bonded to extruded solid or extruded foamed PVC or irradiated PVC sheet. Same or mixed AWG.
ShieldOptional.
CoveringOptional - Extruded PVC, 5 mils minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024