This Style Page is no longer being updated. It is for historic reference only. Please visit: Search - Appliance Wiring Material - Company - Product iQ for the latest Style Page information 
Subj.758 Section 2 Page 2814 Issued:1976-08-26
Revised:2011-11-10
Style 2814 Bonded flat ribbon cable.

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo to 100 insulated singles bonded to PVC or XLPVC sheet, or Polyester film, 0.2 mil minimum thickness, with PVC adhesive, 3 mils minimum thickness. May use same or mixed AWG size.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.