APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2816 Issued:1976-08-26
Revised:2011-10-20
Style 2816 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, VW-1 flame.
Conductor24 AWG - 20 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded PE or extruded FRPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo conductors. Distance between conductors (measured from center to center) shall be 0.140 in. minimum for 20 AWG, 0.120 in. minimum for 22 AWG; and 0.100 in. minimum for 24 AWG.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Radio and Television.

UL and the UL Logo are trademarks of UL LLC © 2024