APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2825 Issued:1976-08-16
Revised:2012-04-18
Style 2825 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor32 AWG - 28 AWG, solid or stranded.
InsulationOne conductor - Non-extruded FEP backed polyimide tape, 2.0 mils min. avg, 1 mil min. at any point. The second conductor is uninsulated.
AssemblyTwo conductors.
JacketExtruded FEP, 6 mils min average, 5 mils min. at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment in Class 2 Circuits Only.