APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2833
Issued:
1976-10-14
Revised:
2008-05-27
Style
2833
Jacketed Cable.
Rating
60 deg C, 30 Vac, Horizontal flame.
Insulation
Labeled or complying with Manufacturer's AWM Procedure.
Assembly
Two or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket one inch maximum.
Shield
Optional.
Covering
(Optional) A 6 mils or heavier covering of PE, PTFE, PVC, PFA, FEP or ETFE may be extruded over the conductor assembly or groups of singles.
Jacket
PVC, 15 mils min average, 12 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal Wiring in Class 2 Circuits of Electronic Equipment.
UL and the UL Logo are trademarks of UL LLC © 2024