APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2863 Issued:1977-03-31
Revised:2011-08-11
Style 2863 Parallel Cable with Extruded Integral Insulation and Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, material not specified, same or mixed AWG sizes.
InsulationFRPE or PE or PVC or XLPE or XLPVC, Solid or cellular, 5 mils minimum average thickness, 4 mils minimum thickness at any point, 100 mils maximum.
AssemblyTwo to twenty conductors. Coaxial or twisted, with or without shield, laid in parallel. Filler or barrier layer optional. Insulated conductors is built with optional shield, jacket and optional jacket.
ShieldOptional
JacketInner jacket - PVC, 4 mils minimum average thickness, 3 mils minimum thickness at any point before ripping. Outer jacket - Optional, Extruded PVC, 8 mils minimum thickness at any point before ripping before ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024