APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2870 Issued:1977-05-25
Revised:2013-02-07
Style 2870 Multiple-conductor cable using non-integral jacket

Rating75 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 10 AWG, stranded, same as Type SJT.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
Assembly2 - 6 conductors, same as Type SJT.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal or Internal Wiring of Electronic Equipment.