Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 27 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded FRPE, extruded foamed FRPE, extruded PE, or extruded foamed PE, 31 mils min average, 28 mils minimum at any point. |
|
Assembly | Two to four conductors. |
|
Covering | Optional. A textile braid, extruded nylon jacket (2 mils min. thickness), or min. 8 mils of extruded SRPVC or extruded PVC may be applied between the insulation and shield. |
|
Shield | Shielding over conductor insulation shall consist of 38 - 30 AWG, tinned or untinned copper strands applied as a wrap or braid or a wrap of aluminum faced Polyester tape with or without an uninsulated drain wire. Double shielding consisting of two or combinations of two of the above may be employed. |
|
Jacket | Extruded PVC, 30 mils min average, 24 mils minimum at any point before ripping. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Electronic Equipment. |
|