APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2876 Issued:1977-08-26
Revised:2011-10-24
Style 2876 Multiple-conductor cable using extruded non-integral jacket.

Rating80 deg C, Voltage not specified, Horizontal flame, Cable flame.
Conductor40 AWG minimum
InsulationLabeled or complying with Manufacture's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form an oval or flat cable with no more than three rows of single conductors or groups of conductors. Fillers and barrier layers optional.
ShieldOptional.
JacketExtruded PVC.
Diameter under core assemblyMinimum average thicknessMinimum thickness at any point
0.700 inches or less30 mils24 mils
0.701-1.000 inches60 mils48 mils
1.001-1.500 inches80 mils64 mils
1.501-2.500 inches110 mils88 mils
2.501 inches and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024