APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2878 Issued:1977-09-14
Revised:2012-07-26
Style 2878 Laminated Flat Ribbon Cable.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG - 10 AWG material not specified. May include mixed AWG sizes.
InsulationNon-extruded (laminated) PVC or Non-extruded (laminated) XLPVC sheet, 6 mils min average. Minimum 26 mils between conductors, 6 mils minimum edge width.
Assembly2-50 uninsulated wires laid parallel in one and plane, laminated between 2 sheets of PVC or XLPVC, each sheet is 6 mils minimum at any point. Minimum 26 mils between conductors, 6 mils minimum edge width. Irradiation optional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits.

UL and the UL Logo are trademarks of UL LLC © 2024