			| Rating | 60, 80, 90 or 105 deg C, 30 Vac, Horizontal flame. | 
		
			 | 
		
			| Insulated Conductor | 40 AWG - 20 AWG. Labeled of complying with Manufacture's AWM Procedure. | 
		
			 | 
		
			| Assembly | Two to four parallel, or two or more insulated singles twisted together. Lay not specified. Fillers and/or barrier layers optional. Manufacturer shall maintain a complete description of each assembly. Maximum "O.D" 500 mils. May include mixed AWG sizes. | 
		
			 | 
		
			| Shield | Optional. | 
		
			 | 
		
			| Jacket | Extruded PVC, 5 mils minimum average thickness, 3 mils minimum thickness at any point. | 
		
			 | 
		
			| Standard | Appliance Wiring Material UL 758. | 
		
			 | 
		
			| Marking | General. | 
		
			 | 
		
			| Use | Internal wiring of electronic equipment in Class 2 systems only. | 
		
			 |