APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2883 Issued:1977-09-14
Revised:2011-10-14
Style 2883 Laminated Flat Cable.

Rating90 deg C, 300 Vac, Horizontal flame.
Conductor30-16 AWG, solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with Manufacture's AWM Procedure.
AssemblyTwo to 200 single insulated conductors laid parallel in one plane and bonded to a PVC sheet or polyester/ PVC laminated film (3 mil min at any point) in such a fashion to form a flat ribbon-type cable. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.