APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2885 Issued:1977-08-29
Revised:2019-11-07
Style 2885 Jacketed Cable.

Rating105 deg C, Voltage not specified, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPVC
major dia in inches
0.250 or less15 mils min average12 mils minimum at any point
0.251-0.425 dia30 avg24 min
0.426-0.700 dia45 avg36 min
0.701-1.000 dia60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliance and electronic equipment.