APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2887 Issued:1977-09-14
Revised:2012-07-10
Style 2887 Bonded or Laminated Flat Cable.

Rating90 deg C, 300 Vac, Horizontal Flame.
Conductor32 AWG - 12 AWG, Solid or Stranded, Round or Flat.
InsulationNon-Extruded (Laminated) Polyester and PET, 3 mils minimum average or Extruded PVC, 3 mils minimum average.
AssemblyTwo to 150 conductors. Minimum thickness of 1.5 mils; maximum thickness of 6.0 mils. Conductors may be straight or irregular shaped and laid parallel and in one plane. Minimum width of 10 mils and maximum width of 100 mils. On each side of the conductors 3.5 mils minimum of PVC bonded or 1.5 mils minimum of polyester adhesive bonded to 1.5 mils minimum of biaxially oriented polyethylene terephthalate (Polyester) Minimum 16 mils insulation on width on outside edges of conductors and 16 mils minimum insulation width between adjacent conductors. Length of insulated conductors not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024