APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2892 Issued:1977-09-22
Revised:2019-11-07
Style 2892 Multiple conductor with Extruded Insulation and Extruded Non-Integral Jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor32 AWG - 20 AWG solid or stranded round.
InsulationSRPVC, 7 mils minimum average thickness , 5.0 mil minimum thickness at any point.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
major dia in inches
0.250 or less15 mils minimum average thickness12 mils minimum thickness at any point
0.251-0.425 dia30 avg24 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment in Class 2 circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024