APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2893 Issued:1977-12-13
Revised:2011-08-11
Style 2893 Multiple-Conductor Cable with Extruded Insulation and Extruded Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
ConductorTwo conductor. 30 AWG - 16 AWG, solid or stranded round
InsulationExtruded foamed FRPE or extruded foamed XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Electronic Use in Non-Hazardous Locations.