Rating | 200 deg C, 300 Vac, Cable flame, Oil Resistant 80 deg C (optional). |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded FEP |
| Diameter of core assembly under jacket (inches) ¿ | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.425 or less | 15 | 12 |
| 0.426-0.700 | 20 | 18 |
| 0.701-1.500 | 30 | 26 |
| 1.501-2.500 | 45 | 40 |
| 2.501 and larger | 60 | 50 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment. In addition, the tag may also indicate the following: Suitable for 600 volts peak - for electronic use only. |
|