APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2899 Issued:1977-12-12
Revised:2012-04-04
Style 2899 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, voltage not specified, Horizontal flame.
InsulationLabeled or complying with Manufacture's AWM Procedure.
AssemblyConsists of two to twenty conductors, individually insulated conductors or groups of conductors cabled together into a round cable. Length of lay not specified. Fillers or wraps optional. Maximum assembly diameter is 0.250 in.
ShieldOptional.
JacketExtruded PVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to movement or mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2024