Rating | 60, 80 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG minimum, flat or round. |
|
Assembly | 2 - 100 uninsulated conductors laid parallel in one plane, laminated between two composite sheets of Non extruded Polyester/PVC or FRPE or one composite non-extruded Polyester/PVC or FRPE sheet and one non-extruded PVC sheet. May include mixed AWG sizes. Minimum 25 mils between conductors, 20 mils minimum edge width. |
|
Covering | Composite non-extruded Polyester/PVC or FRPE sheets on each side or one non-extruded Polyester/PVC sheet on one side and non-extruded PVC sheet on the other side. Minimum 2 mils insulation over the conductors. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Class 2 Circuits in electronic equipment. |
|