APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2902 Issued:1978-01-30
Revised:2012-07-27
Style 2902 Laminated Flat Cable.

Rating60, 80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, flat or round.
Assembly2 - 100 uninsulated conductors laid parallel in one plane, laminated between two composite sheets of Non extruded Polyester/PVC or FRPE or one composite non-extruded Polyester/PVC or FRPE sheet and one non-extruded PVC sheet. May include mixed AWG sizes. Minimum 25 mils between conductors, 20 mils minimum edge width.
CoveringComposite non-extruded Polyester/PVC or FRPE sheets on each side or one non-extruded Polyester/PVC sheet on one side and non-extruded PVC sheet on the other side. Minimum 2 mils insulation over the conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024