APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2903 Issued:1978-01-30
Revised:2012-10-24
Style 2903 Parallel cable with extruded integral insulation and jacket

Rating60 deg C, 300 Vac, FT2 flame.
Conductor20 - 18 AWG, stranded.
Integral Insulation and JacketExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point before separation, 13 mils minimum thickness at any point after separation, 45 mils minimum web thickness between conductors.
AssemblyFour conductors, same as type SPT-1.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or external interconnection of household sewing machines and similar equipment.

UL and the UL Logo are trademarks of UL LLC © 2024