APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2904 Issued:1978-01-30
Revised:2011-10-14
Style 2904 Multiple-conductrocable using non-integral jacket, Parallel Coaxial Cable.

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG min. material not specified.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo insulated singles twisted together (length of lay not specified), shielded and jacketed laid parallel with the other conductor consisting of an insulated single with shield and jacket.
ShieldOptional.
JacketExtruded PVC, 12 mils min average, 10 mils minimum at any point. Measured after ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Low Energy Non-Hazardous Circuits in Audio and Video Equipment.