APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2906 Issued:1978-01-30
Revised:2019-10-11
Style 2906 Multiconductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. Extruded PVC, 6 mils thickness.
JacketPVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.350 inch or less15 mils12 mils
0.351-0.700 inch30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.