APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2914 Issued:1978-03-22
Revised:2019-11-07
Style 2914 Jacketed Cable.

Rating105 deg C, 125 Vac, Horizontal flame.
Conductor40 AWG minimum - Material not specified.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted insulated singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketETFE
dia in inches
0.425 or less13 mils min average10 mils minimum at any point
0.426-0.700 dia20 avg18 min
0.701-1.500 dia30 avg24 min
1.501-2.500 dia45 avg36 min
2.501 dia and larger60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024