APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2915 Issued:1978-03-22
Revised:2019-11-07
Style 2915 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor40 AWG minimum - Material not specified.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted insulated singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketETFE
dia in inches
0.425 or less13 mils min average10 mils minimum at any point
0.426-0.700 dia20 avg18 min
0.701-1.000 dia30 avg24 min
1.001-1.500 dia45 avg36 min
1.501-2.500 dia60 avg48 min
2.501 dia or larger78 avg62 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.