			| Rating | 80 deg C, 30 Vac, Cable flame. | 
			|  | 
			| Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. 40 AWG minimum. | 
			|  | 
			| Assembly | Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. Barrier layers, binders over groups of conductors and/or the complete conductor assembly, and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. | 
			|  | 
			| Covering | Optional. A 6 mil or heavier PVC covering may be extruded over groups of conductors and/or over the complete conductor assembly. | 
			|  | 
			| Shield | Optional. May be provided over groups of conductors and/or over the complete conductor assembly. | 
			|  | 
			| Jacket | Extruded PVC. | 
			|  | Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point | 
			|  | 0.425 inch or less | 30 mils | 24 mils | 
			|  | 0.426-0.700 inch | 45 mils | 36 mils | 
			|  | 0.701-1.000 inch | 60 mils | 48 mils | 
			|  | 1.000-1.500 inch | 80 mils | 64 mils | 
			|  | 1.501-2.500 inch | 110 mils | 88 mils | 
			|  | 2.501 inch and larger | 140 mils | 112 mils | 
			|  | * - Major diameter if cable is flat or oval. | 
			|  | 
			| Braid | Optional. | 
			|  | 
			| Standard | Appliance Wiring Material UL 758. | 
			|  | 
			| Marking | General. | 
			|  | 
			| Use | Internal wiring or external interconnection in Class 2 Circuits of electronic computers and electric business machines. | 
			|  |