APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2927 Issued:1978-08-30
Revised:2012-04-18
Style 2927 Laminated flat ribbon cable

Rating150 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 20 AWG bare, tinned or plated, round or flat copper conductors. Min thickness of 1.0 mil, max thickness of 12.0 mils.
InsulationPOLYIMIDE, 3 mils min average.
AssemblyTwo to sixty conductors. Min width of 10.0 mils, max width of 375 mils. On each side of conductors, a 3.0 mil min wall of polyimide film with a 1.0 mil modifiied acrylic adhesive. Insulation width on outside edges of conductors not less than 10.0 mils and not less than 15.0 mils width of insulation between adjacent conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment (such as computers and business machines) and appliances.