APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2933 Issued:1978-06-12
Revised:2011-10-06
Style 2933 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 30 Vac, VW-1 flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo-twenty insulated singles cabled together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket 1 in. maximum.
ShieldOptional.
CoveringOptional. A nominal 15 mils extruded PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring in Class 2 Circuits of Audio and Video Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024